Axial

CANARM(CLICK FOR DETAILS) DESCRIPTION ACME CARNES COOK COOLAIR FANTECH GREENHECK PENN S&P TWIN CITY
P Direct Drive Sidewall Exhaust/Supply FQ / FN / DMD-E LYDK / LZDK XWD CDP / CDU 2VLD SE1 / SS1 P GED / GSD TCPE
AX / SD Shutter Mount Direct Drive Sidewall Exhaust - - - - 2SHE - - - -
BTA Belt Drive Tube Axial HA LIBA ADB / EDB TBC/TEBC/TEBH - TAB BTA TDB TB
DDA Direct Drive Tube Axial HD LIDA ADD / EDD TDC - TAD TA TDD TD
ADD Direct Drive Wall Exhaust/Supply - Cast Alum Prop - LJDL-A / LKDL-A AWD / EWD CDC - SCE / SCS / SCR BC DDE / DDS WPDB / WPDE
DDS Direct Drive Wall Exhaust/Supply - Steel Propeller FN / FQ / DMD-E - XWHD CDU - SE2 / SS2 P DFE / DFS WPDZ
DDP Direct Drive Wall Exhaust/Supply - Composite Propeller - LJDL-P / LKDL-P - - - - - - -
RB Belt Drive Upblast Exhaust Propeller UBG LUBA / LUBK LXU/LEU/LSU JBH / JBHX / JBC - RBU HS / HZ UBS / UBB LUB
RD Direct Drive Upblast Exhaust Propeller UD LUDA LXU/LEU/LSU JDC - RDU HZ UBX LUD
RTA Belt Drive Upblast Exhaust Propeller - Motor Out of Airstream UBH LQBA AUB / EUB JTBC / JTEBC - TAUB HX TUB TUB
RTA Belt Drive Upblast Exhaust Propeller - Motor Out of Airstream UBG-MX LUKA - JBCMO - RBU-MO - TUB LUB-MO
RTA-SH Belt Drive Upblast Exhaust Propeller - High Temp UBHSE LQBA SUB-H / TUB-H HS / HSE - TAUB-HT - TUB-HT TUB-SH
RTA-SH Belt Drive Upblast Exhaust Propeller - High Temp UBGSE - - - - RBU-MO HS-HS UBSRD-HT LUB-SH
XBL Belt Drive Wall Exhaust - Light Duty DC     CBL 1SDE SBE1 / SBS1 BLL LC WPB-L1
XB / HV Belt Drive Wall Exhaust/Supply - Steel Propeller DCK / DCH / K LWBK / LMBK XL / XM CBL / CBH / CBHX 1SDE SBE / SBS BHM / BHH LC / L2 / L3 WPB-L1,L2,Z
HVA Belt Drive Wall Exhaust/Supply - Cast Aluminum Propeller - LNBK / LRBK AWB / EWB CBC - SBC BCH - WPB-B,E,C

Centrifugal

CANARM(CLICK FOR DETAILS) DESCRIPTION ACME CARNES COOK COOLAIR FANTECH GREENHECK PENN S&P TWIN CITY
ALX-DB (SB) Belt Drive DownBlast Spun Alum Exhaust PV VEBK ACEB CRBCA 5BDD GB DX-B (S)DB BCRD
ALX-UB (SBRM) Belt Drive UpBlast Spun Alum Exhaust PNU-RF VUBK ACRUB CUBA / UBCA 5BDU CUBE FX-B (S)TXB BCRU
ALX-UB (SBRM) Belt Drive Wall Mount Spun Alum Exhaust PNU-RFW VWBK ACWB CWBA 5BDU CWB WFX-B (S)TXBW BCRW
ALX-DD (SD) Direct Drive DownBlast Spun Alum Exhaust PRN / PVD VEDK ACED CRDA 5DDD G DX LPD/RED/SDBD DCRD
ALX-UD (SDUB) Direct Drive UpBlast Spun Alum Exhaust PDU-RF VUDK ACRUD CUDA / UDCA 5DDU CUE FX (S)TXD-RHUL DCRU
ALX-UD (SDUB) Direct Drive Wall Mount Spun Alum Exhaust PDU-RFW VWDK ACWD CWDA 5DDU CW WFX CWD / (S)TXDW DCRW
ALX-UD (SBRM) Belt Drive UpBlast Spun Alum Exhaust - UL762 PNU-RG VRBK VCR CUBA / UBCA 5BDU CUBE FX-BFT (S)TXB-RHUL BCRUR
ALX-UB (SBRM) Belt Drive Wall Mount Spun Alum Exhaust - UL762 PNU-RGW VRBK VCR CUBA / UBCA 5BDU CWB WFX-BFT (S)TXB-RHUL BCRWR
ALX-UD (SDUB) Direct Drive UpBlast Spun Alum Exhaust - UL762 PDU-RG - VCRD CUDA / UDCA 5DDU CUE FX-FT (S)TXD-RHUL DCRUR
ALX-UD (SDUB) Direct Drive Wall Mount Spun Alum Exhaust - UL762 PDU-RGW - VCRD CUDA / UDCA 5DDU CW WFX-FT (S)TXDW-RHUL DCRWR
SIG / SIS Belt Drive Filtered Supply - Side Inlet AFSI VNBL KSP SIS 5FSU SAF FS KSF BCRFS
SISDD Direct Drive Filtered Supply - Side Inlet - - - - - - - - -
700 Belt Drive Filtered Supply - Hooded AFSN VSBB ASP CFS - RSF MU CSF -
700DD Direct Drive Filtered Supply - Hooded - - - - - - - - -
-- Belt Drive Filtered Supply - Louvered AFSL VHBB ASP-T - - RSFP - LSF -
DSQ-B Belt Drive Square Inline Duct Fan XB VIBK SQNB / SQI-B SQBA - BSQ SX-B SQB BSI
GSQ-D Direct Drive Square Inline Duct Fan XD VIDK SQND / SQI-D SQDA - SQ SX SQD DSI
200 / IDB / 9200 Belt Drive Inline Cabinet Duct Blower DM / DMS VDBA DB - - BDF ZC / ZCC CFD DBS / DBT
IDB-X Belt Drive Inline Cabinet Duct Blower - External Motor - - DBX - - - - - -
IDL Belt Drive Low Profile Inline Cabinet Duct Blower - - - - - BCF - - -
400 Belt Drive Forward Curve Utility Blower - Arrangement 3 - - - - - - - - -
600 Belt Drive Forward Curve Utility Blower FCF VFBB CPFB VSFC / VSFCJ - SFB - - FCV
BI / BI-AW Belt Drive Backward Incline Vent Set QBR / 3000 / 8100 VBBB CPV / CPS VSBC / VSBCJ - SWB / USF D CM BCV
BI-RMHS Belt Drive Backward Incline Vent Set - Heat/Smoke QBRSE / 8100SE - CPS - - SWB / USF - CM-HT BCVHS
BI-RM / BI-RMAW Belt Drive Backward Incline Vent Set - UL762 QBR / 8100 VBBB CPV / CPS VSBC / VSBCJ - SWB / USF D CM-RHUL BCVR
HSE Belt Drive BI Curb Mount Vent Set - UL762 - - LoPro - - - GBH - BHRE
USD Direct Drive BI Utility Blower QBRD - - - - SWD D - DCV
D Direct Drive Forward Curve Utility Blower - - CPFD VSDDF - SFD - - DDF
KE Direct Drive Radial Blower - - - - - - - - -
PW Direct Drive Pressure Blower - - - - - FPB - - -
G-Series Belt Drive Forward Curve DWDI Blower - - - - - - - - TFC / VFC class L
800 Belt Drive Forward Curve DWDI Blower - - - - - - - - TFC / VFC class R
900 Belt Drive Forward Curve DWDI Blower - - - - - - - - TFC / VFC class K
900BI Belt Drive Backward Incline DWDI Blower - - - - - - - - VBC class K
900AF Belt Drive Airfoil DWDI Blower - - - - - - - - VAF class K
BIDI Belt Drive DWDI BI Blower - Heavy Duty - - CF / CA - - BIDW / AFDW VCR-DW - BC / BAF / BAE
DPL / DPL-AF Belt Drive BI / AF Plenum Blower 8800 / 8800STAR - PLC - - APH / APM ESP - EPF / EPQ
DPL-DD Direct Drive BI Plenum Blower - - PLC - - APH / APM / APD ESP - EPL/EPFN/EPQN
PMD Direct Drive BI Plenum Blower - Light Duty - - - - - - - - -