TYPICAL MAXIMUM CFM @ SP | ||||||||||||||||||||||
MODEL | 1/2” SP | 1” SP | 1 1/2” SP | 2" SP | 2 1/2" SP | Min HP | Max HP | |||||||||||||||
CFM | BHP | FEI | FEPact (kW) | CFM | BHP | FEI | FEPact (kW) | CFM | BHP | FEI | FEPact (kW) | CFM | BHP | FEI | FEPact (kW) | CFM | BHP | FEI | FEPact (kW) | |||
SIS-9 | 2300 | 1.36 | 0.64 | 1.30 | 2200 | 1.48 | 0.74 | 1.40 | 2000 | 1.47 | 0.84 | 1.39 | 1800 | 1.45 | 0.91 | 1.37 | 1600 | 1.45 | 0.96 | 1.37 | 1/4 | 1 1/2 |
SIS-10 | 2700 | 1.46 | 0.67 | 1.38 | 2400 | 1.42 | 0.79 | 1.35 | 2200 | 1.49 | 0.87 | 1.41 | 1900 | 1.40 | 0.96 | 1.33 | 1700 | 1.44 | 0.99 | 1.37 | 1/4 | 1 1/2 |
SIS-12 | 3600 | 1.94 | 0.62 | 1.80 | 3300 | 1.98 | 0.75 | 1.83 | 2900 | 1.90 | 0.86 | 1.76 | 2600 | 1.96 | 0.91 | 1.81 | 2100 | 1.94 | 0.88 | 1.80 | 1/4 | 2 |
SIS-15 | 5300 | 2.98 | 0.61 | 2.68 | 4800 | 2.88 | 0.74 | 2.59 | 4400 | 2.90 | 0.85 | 2.61 | 3900 | 2.91 | 0.90 | 2.62 | 3500 | 3.00 | 0.92 | 2.70 | 1/2 | 3 |
SIS-18 | 8300 | 4.95 | 0.60 | 4.33 | 7700 | 4.86 | 0.73 | 4.26 | 7100 | 4.97 | 0.81 | 4.35 | 6500 | 4.93 | 0.89 | 4.32 | 5800 | 4.94 | 0.93 | 4.32 | 1/2 | 5 |
SIS-20 | 12500 | 9.91 | 0.46 | 8.45 | 11700 | 9.83 | 0.56 | 8.38 | 11000 | 9.89 | 0.64 | 8.43 | 10300 | 9.94 | 0.71 | 8.48 | 9500 | 9.90 | 0.76 | 8.48 | 2 | 10 |
CFM values listed are summarized for convenience. For full performance data refer to our Delair program. | ||||||||||||||||||||||
Power rating (BHP) does not include transmission losses. Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effect of appurtenances (accessories). | ||||||||||||||||||||||
For expanded FEI dataclick here. | ||||||||||||||||||||||