Specifications

TYPICAL MAXIMUM CFM AT STATIC PRESSURE (in wg.)
MODELSIZEMOTOR0" SP1/10" SP1/4" SPROUGH OPENING
speedvoltshpRPMCFMFEP (kW)FEICFM/WCFMFEP (kW)FEICFM/WCFMFEP (kW)FEICFM/W
PLF12-EVDL
Test #: 24191
12"variable115/230V1/416258700.161.055.63200.120.742.01100.110.620.615 in2
PLF16-EVDL
Test #: 24187
16"variable115/230V1/4162523300.311.168.617600.311.257.27400.220.822.819 1/4 in2
PLF18-FVDL
Test #: 24186
18"variable115/230V1/3162528300.371.178.920700.351.187.011400.290.913.621 1/4 in2
PLF24-M
Test #: 24190
24"variable115/230V1/3107552400.591.3712.237300.541.419.722500.461.115.427 1/4 in2
PLF24-GVDL
Test #: 24188
24"variable115/230V1/2162558200.641.099.950300.691.208.731400.601.115.927 1/4 in2
PLF36-MP1
Test #: 24192
36"single115/230V1/285591100.942.1320.774200.971.9014.643900.781.196.740 1/4 in2
PLF36-H
Test #: 24189
36"single230V1790127601.271.5715.8111101.381.6213.077601.281.368.340 1/4 in2
Certified performance by BESS Labs, University of Illinois.
Test results completed at 230V without accessories.