Specifications

TYPICAL MAXIMUM CFM @ SP
MODEL1/2” SP1” SP1 1/2” SP2" SP2 1/2" SPMin HPMax HP
CFMBHPFEIFEPact (kW)CFMBHPFEIFEPact (kW)CFMBHPFEIFEPact (kW)CFMBHPFEIFEPact (kW)CFMBHPFEIFEPact (kW)
IDB07 / IDBX0714000.680.800.6913000.690.960.7011000.661.050.6710000.721.080.738000.731.040.741/63/4
IDB09 / IDBX0920000.750.910.7618000.751.090.7615000.711.210.7211000.711.120.728000.711.040.721/63/4
IDB10 / IDBX1030001.460.771.3828001.410.961.3426001.491.041.4123001.501.091.4219001.471.081.391/61 1/2
IDB12 / IDBX1237001.440.861.3733001.470.991.3929001.501.071.0324001.471.101.3916001.430.931.361/61 1/2
IDB15 / IDBX1561002.900.772.6158002.950.932.6550002.980.962.6841002.930.942.6437002.931.002.641/33
CFM values listed are summarized for convenience. For full performance data refer to our Delair program.
Power rating (BHP) does not include transmission losses.  Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effect of appurtenances (accessories).
For expanded FEI data click here.
Embedded image
Embedded image
Note: IDB-X models are not ETL or AMCA certified at this time.