Specifications

TYPICAL MAXIMUM CFM @ SP
MODEL1/2” SP1” SP1 1/2” SP2 SP2 1/2 SP
CFMBHPFEIFEPact (kW)CFMBHPFEIFEPact (kW)CFMBHPFEIFEPact (kW)CFMBHPFEIFEPact (kW)CFMBHPFEIFEPact (kW)
90729174.860.474.2628434.760.534.1727574.660.584.0926884.720.624.1426104.760.664.17
909-738004.780.634.1937004.740.694.1636004.710.754.1335004.680.814.1134004.660.854.09
90951469.870.438.4250529.680.488.2649659.580.548.1848519.450.588.0747269.450.628.07
910-857009.620.588.2156009.590.638.1955009.570.678.1754009.520.728.1353009.470.778.09
91064639.830.558.3863359.800.618.3661839.740.668.3160319.740.708.3158939.830.748.38
912-976009.670.728.2575009.910.778.4573009.820.828.3871009.780.878.3469009.760.918.33
91286969.930.688.4784289.880.748.4381519.850.798.4078649.800.848.3675969.800.888.36
915-1081279.880.518.4378289.890.578.4374989.800.628.3671049.980.648.5167419.960.688.49
9151218114.800.6312.501185714.860.6912.501150614.800.7412.501116414.810.7912.501079414.860.8312.50
918-131330014.820.6712.501280014.850.7112.501230014.820.7612.501200014.820.8212.501180014.940.8812.60
9181739919.910.6816.701682019.830.7316.601631519.890.7816.701581219.950.8316.701526319.920.8716.70
920-181968519.790.6016.601908919.890.6816.701837519.760.7416.501775919.870.8016.601705019.710.8616.50
9202510139.820.4732.902452839.810.5232.902399239.830.5732.902347439.850.6232.902293839.790.6632.90
9222839039.980.4833.002777439.790.5532.902725639.920.6033.002671439.920.6633.002614739.840.7232.90
9253334739.950.4933.003282739.920.5733.003223539.780.6532.903134638.870.7332.103092539.720.7932.80
9274778749.930.7041.104617249.700.7640.904443449.880.8141.104282549.760.8541.004143949.790.9041.00
9305600058.810.7248.305450059.190.7848.605300059.830.8349.105100059.010.8848.504900058.160.9347.80
9337200095.310.5877.807000093.810.6476.606900096.450.6978.706800099.710.7381.306600099.780.7781.40
9367560493.740.6076.507526499.510.6581.107339799.700.7081.307148199.670.7581.306962699.800.8081.40
CFM values listed are summarized for convenience. For full performance data refer to our Delair program.
Power rating (BHP) does not include transmission losses.  Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effect of appurtenances (accessories).
For expanded FEI data click here.