Specifications
TYPICAL MAXIMUM CFM @ SP | ||||||||||||||||||||||
MODEL | 1/2” SP | 1” SP | 1 1/2” SP | 2" SP | 2 1/2" SP | Min HP | Max HP | |||||||||||||||
CFM | BHP | FEI | FEPact (kW) | CFM | BHP | FEI | FEPact (kW) | CFM | BHP | FEI | FEPact (kW) | CFM | BHP | FEI | FEPact (kW) | CFM | BHP | FEI | FEPact (kW) | |||
610 | 2600 | 1.99 | 0.61 | 1.84 | 2400 | 1.87 | 0.72 | 1.74 | 2300 | 1.95 | 0.80 | 1.80 | 2200 | 2 | 0.88 | 1.85 | 2000 | 1.83 | 0.99 | 1.70 | 1/6 | 2 |
612 | 3000 | 1.89 | 0.70 | 1.75 | 2800 | 1.86 | 0.82 | 1.73 | 2700 | 1.99 | 0.90 | 1.84 | 2500 | 1.98 | 0.97 | 1.83 | 2300 | 1.92 | 1.06 | 1.78 | 1/3 | 2 |
615 | 6400 | 4.93 | 0.68 | 4.32 | 6000 | 4.89 | 0.75 | 4.28 | 5700 | 4.97 | 0.82 | 4.35 | 5400 | 4.93 | 0.89 | 4.32 | 5100 | 4.87 | 0.96 | 4.27 | 1/3 | 3 |
618 | 6700 | 4.92 | 0.60 | 4.31 | 6300 | 4.97 | 0.68 | 4.35 | 5900 | 4.93 | 0.77 | 4.32 | 5500 | 4.85 | 0.84 | 4.25 | 5200 | 4.91 | 0.91 | 4.30 | 1/2 | 5 |
620 | 10300 | 9.78 | 0.48 | 8.34 | 9900 | 9.8 | 0.57 | 8.36 | 9600 | 9.98 | 0.64 | 8.51 | 9200 | 9.82 | 0.73 | 8.38 | 8900 | 10 | 0.79 | 8.53 | 1/2 | 7 1/2 |
622 | 11500 | 9.83 | 0.49 | 8.38 | 11000 | 9.99 | 0.58 | 8.52 | 10400 | 9.79 | 0.67 | 8.35 | 10000 | 10 | 0.74 | 8.53 | 9400 | 9.83 | 0.81 | 8.38 | 1/2 | 7 1/2 |
625 | 14300 | 9.95 | 0.57 | 8.48 | 13500 | 9.99 | 0.68 | 8.52 | 12500 | 9.86 | 0.76 | 8.41 | 11900 | 10 | 0.84 | 8.53 | 11400 | 9.96 | 0.94 | 8.49 | 1 | 10 |
CFM values listed are summarized for convenience. For full performance data refer to our Delair program. | ||||||||||||||||||||||
Power rating (BHP) does not include transmission losses. Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effect of appurtenances (accessories). | ||||||||||||||||||||||
For expanded FEI data click here. | ||||||||||||||||||||||