Specifications
TYPICAL MAXIMUM CFM @ SP | ||||||||||||||||||||||||
MODEL | 1/2” SP | 1” SP | 1 1/2” SP | 2" SP | 2 1/2" SP | Min HP | Max HP | |||||||||||||||||
CFM | BHP | FEI | FEPact (kW) | CFM | BHP | FEI | FEPact (kW) | CFM | BHP | FEI | FEPact (kW) | CFM | BHP | FEI | FEPact (kW) | CFM | BHP | FEI | FEPact (kW) | |||||
307 | 1200 | 0.73 | 0.52 | 0.74 | 1100 | 0.71 | 0.73 | 0.72 | 900 | 0.66 | 0.89 | 0.67 | 700 | 0.69 | 0.88 | 0.70 | 500 | 0.73 | 0.81 | 0.74 | 1/4 | 3/4 | ||
309 | 1800 | 0.71 | 0.72 | 0.72 | 1600 | 0.75 | 0.92 | 0.76 | 1300 | 0.71 | 1.08 | 0.72 | 1000 | 0.73 | 1.07 | 0.74 | 700 | 0.73 | 0.99 | 0.74 | 1/4 | 3/4 | ||
310 | 2800 | 1.44 | 0.54 | 1.37 | 2500 | 1.43 | 0.73 | 1.36 | 2200 | 1.41 | 0.88 | 1.34 | 2000 | 1.5 | 0.95 | 1.42 | 1600 | 1.5 | 0.94 | 1.42 | 1/4 | 1 1/2 | ||
312 | 3700 | 1.88 | 0.53 | 1.74 | 3300 | 1.94 | 0.70 | 1.80 | 2900 | 1.92 | 0.83 | 1.78 | 2500 | 1.93 | 0.91 | 1.79 | 1700 | 1.94 | 0.78 | 1.80 | 1/4 | 2 | ||
315 | 5700 | 2.98 | 0.50 | 2.68 | 5200 | 2.99 | 0.69 | 2.69 | 4600 | 2.9 | 0.84 | 2.61 | 4100 | 2.94 | 0.94 | 2.65 | 3400 | 2.97 | 0.94 | 2.67 | 1/2 | 3 | ||
318 | 8800 | 4.9 | 0.46 | 4.29 | 8100 | 4.96 | 0.63 | 4.34 | 7300 | 4.88 | 0.78 | 4.27 | 6700 | 4.92 | 0.90 | 4.31 | 5900 | 4.93 | 0.95 | 4.32 | 1/2 | 5 | ||
CFM values listed are summarized for convenience. For full performance data refer to our Delair program. | ||||||||||||||||||||||||
Power rating (BHP) does not include transmission losses. Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effect of appurtenances (accessories). | ||||||||||||||||||||||||
For expanded FEI data click here. | ||||||||||||||||||||||||