More Views

P Series XP

  • SKU:
  • P Series XP

Quick Overview

P Series Explosion Proof Panel Mounted Fans

Details

  • Sturdily constructed direct drive, horizontal discharge fan.
  • Durable powder coated finish.
  • 8” - 24” models have heavy wire chrome plated OSHA guards on intake side of fan.
  • 30” & 36” models have grey powder coated guards.
  • Totally enclosed air over motor with overload protection.
  • Note: Fans up to 24" can ship via UPS.

Designed for Industrial, Commercial & Farming applications.

The P series exhaust fan is a sturdily constructed, direct drive, horizontal discharge fan that is typically used for industrial, commercial and farming applications. The P Explosion Proof Fans have a single speed, dual voltage explosion proof motor that meets and conforms to all the standards that are listed below.

CLASS I, GROUP C - Atmospheres containing ethyl ether, ethylene, gases or vapors of equivalent hazard.
CLASS I, GROUP D - Atmospheres such as acetone, ammonia, benzene, butane, cyclopropane, ethanol, gasoline, hexane, methane, natural gas, naphtha, propane, or gasses or vapors of equivalent hazard.
CLASS II GROUP F - Atmospheres containing carbonaceous dust, including carbon black, charcoal, coal, or coke dusts that have more than 8% total entrapped volatiles, or dusts that have been sensitized by other materials so that they present an explosion hazard.
CLASS II GROUP G - Atmospheres containing combustible dusts not included in group E or F, including flour, grain, wood, plastic and chemicals.

Dimensions

    
MODELA X A SQUAREBC
c/c
 
 
P12-417 1/4” 13 3/4” 16" 
P14-419 1/4” 13 3/4” 18" 
P16-421 1/4” 13 3/4” 20" 
P18-423 1/4” 14”22" 
P20-425 1/4” 14”24" 
P24-429 1/4” 13 3/4” 28"
~EXPLOSION PROOF MOTOR, 50 HZ OR 3 PHASE

Options

  • Front guards.*
  • Wall sleeve.*
  • Thermostats.
  • Backdraft dampers.*
  • Weather hoods.

*Consult factory to have accessories installed.

Specifications

SINGLE PHASETHREE PHASEBLADE DIAMETERRPMHP (SINGLE PHASE)VOLTAGE (SINGLE PHASE)AMPS (FLA) (SINGLE PHASE)WEIGHT (LBS)dB(A) @5 ftCFM @ STATIC PRESSURE
0.00"0.10"0.125"0.25"
P12-4P12-4*12"17251/3115/2306.6/3.1-3.349631670160015751450
P14-4P14-4*14"17251/3115/2306.6/3.1-3.349672190208020001950
P16-4P16-4*16"17251/3115/2306.6/3.1-3.351682580248024302270
P18-4P18-4*18"17251/3115/2306.6/3.1-3.356733200305029502625
P20-4P20-4*20"17251/3115/2306.6/3.1-3.357773640344033603140
P24-4P24-4*24"17251/3115/2306.6/3.1-3.357775520541053305130
For three phase motors, substitute '*' with 'M' for 230/460 volt (if 208V required please specify) or 'P' for 575 volt. Fan blades tested in accordance with AMCA standard 210, figure 12. dBA ratings shown are measured at 0" static pressure and should be used as a guideline only.