PI3/MIN MAXIMUM TYPIQUE À SP | ||||||||||||||||||||||
MODÈLE | 1/2 po SP | SP 1 po | 1 1/2 po SP | SP 2 po | 2 1/2 po SP | Min HP | Max HP | |||||||||||||||
CFM | BHP | FEI | FEPact (kW) | CFM | BHP | FEI | FEPact (kW) | CFM | BHP | FEI | FEPact (kW) | CFM | BHP | FEI | FEPact (kW) | CFM | BHP | FEI | FEPact (kW) | |||
IDB07/IDBX07 | 1400 | 0,68 | 0,80 | 0,69 | 1300 | 0,69 | 0,96 | 0,70 | 1100 | 0,66 | 1,05 | 0,67 | 1000 | 0,72 | 1,08 | 0,73 | 800 | 0,73 | 1,04 | 0,74 | 1/6 | 3/4 |
IDB09/IDBX09 | 2000 | 0,75 | 0,91 | 0,76 | 1800 | 0,75 | 1,09 | 0,76 | 1500 | 0,71 | 1,21 | 0,72 | 1100 | 0,71 | 1,12 | 0,72 | 800 | 0,71 | 1,04 | 0,72 | 1/6 | 3/4 |
IDB10/IDBX10 | 3000 | 1,46 | 0,77 | 1,38 | 2800 | 1,41 | 0,96 | 1,34 | 2600 | 1,49 | 1,04 | 1,41 | 2300 | 1,50 | 1,09 | 1,42 | 1900 | 1,47 | 1,08 | 1,39 | 1/6 | 1 1/2 |
IDB12/IDBX12 | 3700 | 1,44 | 0,86 | 1,37 | 3300 | 1,47 | 0,99 | 1,39 | 2900 | 1,50 | 1,07 | 1,03 | 2400 | 1,47 | 1,10 | 1,39 | 1600 | 1,43 | 0,93 | 1,36 | 1/6 | 1 1/2 |
IDB15/IDBX15 | 6100 | 2,90 | 0,77 | 2,61 | 5800 | 2,95 | 0,93 | 2,65 | 5000 | 2,98 | 0,96 | 2,68 | 4100 | 2,93 | 0,94 | 2,64 | 3700 | 2,93 | 1,00 | 2,64 | 1/3 | 3 |
Les valeurs énumérées de pi | ||||||||||||||||||||||
La puissance nominale (BHP) ne comprend pas les pertes de transmission. La performance certifiée est pour l'installation de type B : entrée d'air libre, sortie à conduit Les cotes de performance ne comprennent pas l'effet des ouvrages annexes (accessoires). | ||||||||||||||||||||||
Pour des données FEI plus complètes, cliquez ici. | ||||||||||||||||||||||
Remarque : Les modèles IDB-X ne sont pas certifiés ETL ou AMCA pour le moment. |